SuperVault iTank
SViT Series - 13,000L - 88,900L
- Environmentally superior: G300 mild steel twin shells, self-bunded protected tank
- Multi Hazard Tested: 4-hour fire exposure rating, hose-stream resistant, ballistics tested, heavy vehicle impact tested (FRL 240|240|240 as per AS1940)
- Compliant: with international tank approvals SwRI 95-03, SwRI 93-01, UL2085, UL142
- Ventilation: emergency venting for primary and secondary containment
- Clean fuel: superior thermal efficiency minimising evaporation and degradation of fuel quality
- Interstitial monitoring: capability
- Maximum protection: a 3-coat 15+ year industrial painting system for longevity
- Diversified material options: material of construction may be carbon or stainless steel
- Easily transportable: relatively light-weight and can be shipped anywhere in the world (empty).
- Seismic rating: certified to Importance Level 4 as per AS1170
- Warranty: 30 years
Supervault iTank SViT Series
Industries across the world need to ensure they are compliant when it comes to storing hazardous liquids such as petrol, diesel or chemicals. Fuelchief take the hassle out of this by engineering a compliant customised fuel tank called the SuperVault®. This engineered fuel tank is 4-hour fire-rated and is recommended due to its fire protective safety for commercial sectors.
The SuperVault iTank has been re-designed and certified as a rectangular ‘obround’ shape to cater for much tighter space requirements inside buildings resulting in the design of these rooms being much simpler, more cost effective and futureproof without the need to fire-rate the room.
The SuperVault® tank offers elite fire-rated, bullet-proof, impact-resistant technology and has been designed, fabricated and tested in accordance with SwRI 95-03 which makes it the safest and most durable tank in the world. In many circumstances where diesel or petrol needs to be stored in commercial buildings, the SuperVault® is the only permitted tank. The SuperVault has been engineered to withstand conditions – from the sub-zero temperature of the Arctic to the blistering heat of the desert.
No other fuel storage system in the world can provide a higher level of certified fire protection, insulation, and fuel security than a Fuelchief SuperVault®.
Styles and Sizes
| Model | Description | Capacities (Litres) | Width (mm) | Length (mm) | Height (mm) |
|---|---|---|---|---|---|
| SViT 215-13,000 | SuperVault 4 hour fire rated iTank | 13000 | 2440 | 6060 | 1500 |
| SViT 215-13,000 | SuperVault 4 hour fire rated iTank | 19800 | 2440 | 9100 | 1500 |
| SViT 215-26,900 | SuperVault 4 hour fire rated iTank | 27000 | 2440 | 12160 | 1500 |
| SViT 315-16,700 | SuperVault 4 hour fire rated iTank | 16700 | 3000 | 6060 | 1500 |
| SViT 315-25,500 | SuperVault 4 hour fire rated iTank | 25500 | 3000 | 9100 | 1500 |
| SViT 315-34,600 | SuperVault 4 hour fire rated iTank | 34600 | 3000 | 12160 | 1500 |
| SViT 218-16,700 | SuperVault 4 hour fire rated iTank | 16700 | 2440 | 6060 | 1800 |
| SViT 218-25,700 | SuperVault 4 hour fire rated iTank | 25700 | 2440 | 9100 | 1800 |
| SViT 218-34,658 | SuperVault 4 hour fire rated iTank | 34600 | 2440 | 12160 | 1800 |
| SViT 318-21,900 | SuperVault 4 hour fire rated iTank | 22000 | 3000 | 6060 | 1800 |
| SViT 318-33,600 | SuperVault 4 hour fire rated iTank | 33600 | 3000 | 9100 | 1800 |
| SViT 318-45,312 | SuperVault 4 hour fire rated iTank | 45300 | 3000 | 121600 | 1800 |
| SViT 227-27,394 | SuperVault 4 hour fire rated iTank | 27300 | 2440 | 6060 | 2700 |
| SViT 227-41,703 | SuperVault 4 hour fire rated iTank | 41700 | 2440 | 9100 | 2700 |
| SViT 227-56,600 | SuperVault 4 hour fire rated iTank | 56500 | 2440 | 12160 | 2700 |
| SViT 227-67,700 | SuperVault 4 hour fire rated iTank | 67600 | 2440 | 14478 | 2700 |
| SViT 327-35,600 | SuperVault 4 hour fire rated iTank | 35600 | 3000 | 6060 | 2700 |
| SViT 327-54,630 | SuperVault 4 hour fire rated iTank | 54600 | 3000 | 9100 | 2700 |
| SViT 327-73,630 | SuperVault 4 hour fire rated iTank | 73600 | 3000 | 12160 | 2700 |
| SViT 327-88,000 | SuperVault 4 hour fire rated iTank | 88900 | 3000 | 14478 | 2700 |
Downloads
PDF Sheets - click to open in a new tab
Case Studies
Spark Data Centre
Fuelchief collaborated with a series of suppliers to place a custom Fuelchief SuperVault into a brand new data centre facility for Spark.
Joe Deck
Spark Telecom Exchange Building
Fuelchief collaborated with Aurecon engineers to place a customised Fuelchief SuperVault for Spark's telecommunications building.
Joe Deck
Powerco
Fuelchief teamed up with Terra Cat to provide a Fuelchief DCD100 diesel fuel tank to Powerco for critical power backup.
Joe Deck
Relocatable SuperVault For Client
See how our SuperVault was the ideal solution because of it's relocatable design and compliance that it proved to be a real asset.
Joe Deck
University Of Canterbury
Our latest SuperVault case study on a how our 4-hour fire rated tank replaced an underground fuel tank for the University.
Joe Deck
Sandspit Marina
Fuelchief supplies tank to Sandspit Marina, view the latest results of the transaction and why the manager is looking for another tank from us.
Joe Deck
Airways: Critical Control Tower Upgrades
The Fuelchief SuperVault 4 hour fire rated fuel tank was custom made to ensure the critical environment of a aviation control tower was met.
Joe Deck
NZ Bus Auckland Depot Upgrade
See how the SuperVault Cylindrical 4 hour fire rated tank ensured refuelling compliance for NZ Bus. Check out the latest case study.
Joe Deck
Air New Zealand Jet Engine Testing Facility
Fuelchief supplied Air New Zealand, one of the most recognised global airlines in the world, a SuperVault for their new testing facility.
Joe Deck
Christchurch Hospital
Chirstchurch Hospital, consultants needed a SuperVault tank to back up critical generators to ensure continual power in an outage.
Joe Deck
Allied Petroleum iTank in Invercargill
The Fuelchief SuperVault 4 hour fire rated fuel tank was custom made to ensure the critical environment of a aviation control tower was met.
Joe Deck
Downer Bitumen Plant Upgrade Project
Up at Port Whangarei Downer recently took delivery of a SuperVault SVR-4999 and also a DC100 Diesel tank – both supplied via Z Energy for Downers bitumen plant upgrade.
Joe Deck
Citibank Gets a SuperVault
ECL Group were engaged by their client Citibank to supply and install a suitable diesel tank system to supply fuel to a large generator in a multi-storey building in downtown Auckland.
Joe Deck
Terra Cat Praxis Generator Base Tanks
ECL Group were engaged by their client Citibank to supply and install a suitable diesel tank system to supply fuel to a large generator in a multi-storey building in downtown Auckland.
Joe Deck
Air BP Queenstown Airport Project
Queenstown Airport is a pristine location with the importance of environmentally secure and safe storage of fuel. For Air BP the SuperVault’s have been providing this for several years and will continue to do so for many years to come.
Joe Deck
Higgins Group Case Study
The SuperVault solution provided a certified compliant tank for the Test Certifier to sign off on without any issues.
Joe Deck
Nelson City Council
A precision placed series of SuperVault’s measured and constructed to the millimetre for the allocated space available. The tanks have been functioning successfully for the plant.
Joe Deck